Zwicker loudness for stationary and time-varying sounds per ISO 532-1:2017.

Clean-room Python port of the normative reference implementation given in Annex A of ISO 532-1:2017 (program “ISO_532-1”, Annex A.4). Two entry points are provided:

  • loudness_zwicker_from_spectrum - stationary loudness from 28 one-third-octave band levels, 25 Hz to 12.5 kHz (clause 5.3 / A.2).
  • loudness_zwicker - loudness from a calibrated time signal, either with the stationary method (clause 5) or the time-varying method (clause 6), including the one-third-octave filterbank of Annex A (Tables A.1/A.2), the nonlinear temporal decay and the temporal weighting of the total loudness.

All numeric tables live in phonometry._zwicker_data and reproduce Tables A.1 to A.9 of the standard digit for digit.

Auto-generated from the source docstrings by scripts/generate_api_docs.py (make api-docs). Do not edit by hand.

loudness_zwicker(
x: list[float] | np.ndarray,
fs: int,
field: Literal['free', 'diffuse'] = 'free',
stationary: bool = False,
calibration_factor: float = 1.0,
time_skip: float = 0.0,
) -> ZwickerLoudness

Zwicker loudness of a calibrated time signal per ISO 532-1:2017.

The signal is resampled to the internal 48 kHz rate if needed, split into 28 one-third-octave bands with the Annex A filterbank (Tables A.1/A.2), squared and smoothed. With stationary=True the method for stationary sounds (clause 5) is applied to the per-band mean square of the whole signal. Otherwise the method for time-varying sounds (clause 6) is used: core loudness every 0.5 ms, nonlinear temporal decay, specific-loudness slopes, temporal weighting of the total loudness and the percentile values N5/N10 from the full-rate (2000 Hz) weighted loudness series, while the public 500 Hz loudness-vs-time trace is left unchanged.

Input scaling follows the reference implementation’s WAV convention: x * calibration_factor must be the instantaneous sound pressure in pascals, so that band levels are 10*lg(p^2 / (20 uPa)^2) dB SPL. The reference program reads 32-bit float WAV files as pressure in Pa directly (calibration_factor = 1), while 16-bit PCM samples are divided by 32768 (full scale = +-1) and multiplied by a calibration factor derived from a reference recording of known level Lref: calibration_factor = sqrt(10**(Lref/10) * 4e-10 / mean(ref**2)) with ref scaled to +-1 full scale as well.

Parameters

NameDescription
xSingle-channel time signal (see scaling convention above).
fsSampling rate in Hz (positive integer; resampled to 48 kHz with scipy.signal.resample_poly when not 48000).
fieldSound field of the recording: ‘free’ or ‘diffuse’.
stationaryUse the stationary method (clause 5) instead of the time-varying method (clause 6).
calibration_factorMultiplier converting x to pascals.
time_skipLeading time, in seconds, excluded from the stationary mean square (the reference implementation’s TimeSkip). Annex B.1 states the stationary calculation “shall start from 0,2 s” when validating against the official Annex B WAV files, excluding the filterbank transient; the default 0.0 preserves the whole-signal behaviour for synthetic steady signals. Validated always (negative, non-finite or whole-signal skips raise ValueError) but applied only by the stationary method — clause 6 has no TimeSkip.

Returns: ZwickerLoudness. Stationary: as in loudness_zwicker_from_spectrum. Time-varying: loudness is the maximum loudness Nmax, loudness_level its phon mapping, specific the pattern at the loudness maximum, n5/n10 the percentile values and time / loudness_vs_time the loudness trace at 500 Hz.

loudness_zwicker_from_spectrum(
levels: list[float] | np.ndarray,
field: Literal['free', 'diffuse'] = 'free',
) -> ZwickerLoudness

Stationary Zwicker loudness from one-third-octave band levels.

Implements the method for stationary sounds of ISO 532-1:2017 (clause 5) starting from the 28 one-third-octave band levels with center frequencies 25 Hz to 12.5 kHz (base-ten bands, IEC 61260-1).

Parameters

NameDescription
levels28 band levels in dB SPL (re 20 uPa), 25 Hz..12.5 kHz.
fieldSound field the levels were measured in: ‘free’ or ‘diffuse’.

Returns: ZwickerLoudness with loudness (N in sone), loudness_level (LN in phon) and specific (N’ in sone/Bark, 240 values at 0.1-Bark steps); the time-varying fields are None.

ZwickerLoudness(
loudness: float,
loudness_level: float,
specific: np.ndarray,
n5: float | None = None,
n10: float | None = None,
time: np.ndarray | None = None,
loudness_vs_time: np.ndarray | None = None,
field: str | None = None,
)

Result of an ISO 532-1:2017 Zwicker loudness calculation.

loudness is the total loudness N in sone (the stationary value, or the maximum of the time-varying loudness); loudness_level is the loudness level LN in phon obtained from loudness with the sone-to-phon mapping of the reference implementation. specific holds the specific loudness N’ in sone/Bark at 0.1-Bark steps (240 values; for the time-varying method it is the pattern at the instant of maximum loudness). n5/n10 are the percentile loudness values N5/N10 and time/loudness_vs_time the 500 Hz loudness-vs-time trace (clause 6.5); these four are None for stationary results. field records the sound field the calculation assumed ("free" or "diffuse"), one of the items clause 7 requires a loudness report to state; it defaults to None only for backward-compatible manual construction (the library constructors always set it).

ZwickerLoudness.plot(
ax: Axes | None = None,
*,
language: str = 'en',
**kwargs: Any,
) -> Axes | np.ndarray

Plot the specific loudness N’(z) over Bark (see ._plotting).

Adds a loudness-vs-time panel when the time-varying trace is present. Requires matplotlib (pip install phonometry[plot]); returns the Axes (or array thereof).

ZwickerLoudness.report(
path: str,
*,
metadata: ReportMetadata | None = None,
engine: str = 'reportlab',
verbose: bool = False,
language: str = 'en',
) -> str

Render an ISO 532-1 Zwicker loudness fiche to a PDF.

Writes a one-page accredited loudness report with the items clause 7 makes mandatory: the standard-basis line stating the method used (stationary, clause 5, or time-varying, clause 6) and the sound field (free or diffuse, when the result carries it), an optional metadata header block, a compact metrics table (total loudness N, or maximum loudness Nmax with the N5/N10 percentiles for a time-varying result, and the loudness level LN) beside the specific-loudness pattern (the result’s own plot), for a time-varying result the loudness- versus-time function N(t) in sones (clause 7 f)), the boxed N = X sone (LN = Y phon) result, an optional verdict row and a footer with the fixed disclaimer.

Parameters

NameDescription
pathDestination path of the PDF file.
metadataOptional ReportMetadata; None produces a prediction fiche (body, result and disclaimer only). A supplied requirement is read as the maximum permitted loudness in sone.
engineRendering back end; only "reportlab" is supported.
verboseAccepted for a uniform signature; it has no effect on the single-layout loudness fiche.
languageFiche language: "en" (default, English) or "es" (Spanish, with a comma decimal separator).

Returns: The written path as a str.

Raises

ExceptionWhen
ValueErrorIf engine is not "reportlab".
ImportErrorIf reportlab is not installed (pip install phonometry[report]).