Occupational noise exposure: measurement strategies and uncertainty (ISO 9612:2009).

ISO 9612:2009 is the engineering method (accuracy grade 2) for determining a worker’s daily noise exposure level LEX,8h from measurements of the A-weighted equivalent continuous sound pressure level Lp,A,eqT. The raw levels themselves come from the dosimetry primitives in phonometry.levels (leq/lex_8h); this module adds the three measurement strategies, the energy combination of their contributions, and the normative Annex C uncertainty budget.

Three strategies (Clause 8):

  • Task-based (Clause 9): the nominal day is split into tasks; each task level is the energy average of I >= 3 samples (Eq 7), its contribution is LEX,8h,m = Lp,A,eqT,m + 10 lg(T_m/T0) (Eq 8), and the daily level is the energy sum over tasks (Eq 9/10).
  • Job-based (Clause 10): N >= 5 random samples over a homogeneous exposure group; the effective-day level is their energy average (Eq 11) and LEX,8h = Lp,A,eqTe + 10 lg(Te/T0) (Eq 12). The minimum cumulative measurement duration follows Table 1.
  • Full-day (Clause 11): three (or more) whole-day measurements averaged (Eq 11), then Eq 13, the same arithmetic as the job method.

Uncertainty (Annex C, normative). Combined u^2 = sum c_i^2 u_i^2 (C.1), expanded U = k*u with k = 1.65 for a one-sided 95 % confidence interval (Clause 14). Task-based uses Eq C.3 with sampling u1a (C.6), duration u1b (C.7) and sensitivity coefficients c1a (C.4)/c1b (C.5). Job-based and full-day use Eq C.9 with c1*u1 read from Table C.4 and c2 = c3 = 1. The instrument standard uncertainty u2 is from Table C.5 and the microphone position u3 = 1.0 dB (C.6). Peak levels Lp,Cpeak are reported without an uncertainty: Annex C gives no method for them (Table C.5, NOTE 1).

The three worked examples of Annexes D (task), E (job) and F (full-day) are reproduced to the standard’s printed precision in the test suite (Annex E rounds its effective-day level to 88.4 dB before Eq 12 and prints 88.1; the library keeps intermediates unrounded and yields 88.2). Clause/equation/table numbers refer to ISO 9612:2009(E).

Auto-generated from the source docstrings by scripts/generate_api_docs.py (make api-docs). Do not edit by hand.

Constant (float).

COVERAGE_FACTOR = 1.65
ExposureResult(
lex_8h: float,
combined_standard_uncertainty: float,
expanded_uncertainty: float,
strategy: str,
coverage_factor: float = 1.65,
lp_aeqte: float | None = None,
effective_duration_hours: float | None = None,
u1: float | None = None,
c1u1: float | None = None,
u2: float | None = None,
u3: float | None = None,
n_samples: int | None = None,
sampling_advisory: bool = False,
instrument: InstrumentClass | None = None,
tasks: tuple[TaskContribution, ...] = ...,
)

Daily noise exposure level and its expanded uncertainty (ISO 9612:2009).

Attributes

NameDescription
lex_8hA-weighted daily noise exposure level LEX,8h, dB.
combined_standard_uncertaintyCombined standard uncertainty u (Eq C.1), dB.
expanded_uncertaintyExpanded uncertainty U = 1.65*u for a one-sided 95 % confidence interval, dB.
strategy"task", "job" or "full_day".
instrumentInstrument class the measurement was made with (the call default; individual tasks may override it): "class1", "class2" or "personal_exposimeter". Printed on the .report() fiche (ISO 9612:2009 Clause 15 c).
upper_limitLEX,8h + U, the value 95 % of readings fall below.
ExposureResult.plot(
ax: Axes | None = None,
*,
language: str = 'en',
**kwargs: Any,
) -> Axes

Plot the per-task contributions with the LEX,8h line.

Only task-based results carry per-task contributions (the job and full-day strategies raise ValueError). Requires matplotlib (pip install phonometry[plot]); returns the Axes.

ExposureResult.report(
path: str,
*,
metadata: ReportMetadata | None = None,
engine: str = 'reportlab',
verbose: bool = False,
language: str = 'en',
) -> str

Render an ISO 9612 occupational noise-exposure fiche to a PDF.

Writes a one-page measurement report with the information ISO 9612:2009 Clause 15 asks for: the standard-basis line naming the applied strategy, a metadata header (company, worker/job, workplace, instrumentation, calibration), the work analysis (the per-task table of durations, Lp,A,eqT,m levels and LEX,8h,m contributions for the task-based strategy, or the sampling summary for the job-based/full-day strategies), the per-task contribution chart for a task-based result, the boxed LEX,8h with its expanded uncertainty U stated separately (Clause 15 e), an assessment table against the exposure action values (80/85 dB(A)) and the exposure limit value (87 dB(A)) of Directive 2003/10/EC, a PASS/FAIL verdict against the limit value, and a footer identity/disclaimer block.

Parameters

NameDescription
pathDestination path of the PDF file.
metadataOptional ReportMetadata supplying the header identity (client is the company, specimen the worker(s)/job, test_room the workplace) plus the instrumentation and calibration free-text fields and the footer identity.
engineRendering back end; only "reportlab" is supported.
verboseWhen True, the task-based work-analysis table adds the Annex C per-task uncertainty columns (u1a, u1b, u2). The job-based/full-day sampling summary always shows its budget.
languageFiche language: "en" (default, English) or "es" (Spanish, with a comma decimal separator).

Returns: The written path as a str.

Raises

ExceptionWhen
ValueErrorIf engine is not "reportlab" or language is unknown.
ImportErrorIf reportlab (or, for a task-based result’s chart, matplotlib) is not installed (pip install phonometry[report]).

property

Upper limit LEX,8h + U of the one-sided 95 % interval, dB.

full_day_exposure(
samples: Sequence[float],
effective_duration_hours: float,
instrument: InstrumentClass = 'personal_exposimeter',
u3: float = 1.0,
warn: bool = True,
) -> ExposureResult

Daily noise exposure level from full-day measurements (ISO 9612:2009 Clause 11).

Three (or more) whole-day Lp,A,eqT measurements are energy-averaged (Eq 11) and the daily level follows Eq 13. If only three measurements are supplied and they span 3 dB or more, Clause 11.3 requires at least two more; this raises the sampling advisory. The uncertainty is the job-based budget (Eq C.9, Table C.4).

Parameters

NameDescription
samplesWhole-day Lp,A,eqT,n measurements, dB (three minimum per Clause 11.3; two is enforced numerically).
effective_duration_hoursEffective working-day duration T_e, hours.
instrumentInstrument class selecting u2 (Table C.5).
u3Microphone-position standard uncertainty, dB (Clause C.6 gives 1.0).
warnEmit OccupationalExposureWarning for the 3 dB spread rule and the Table C.4 advisory.

Returns: An ExposureResult.

Constant (dict).

INSTRUMENT_U2 = {'class1': 0.7, 'class2': 1.5, 'personal_exposimeter': 1.5}
job_based_exposure(
samples: Sequence[float],
effective_duration_hours: float,
instrument: InstrumentClass = 'personal_exposimeter',
u3: float = 1.0,
n_workers: int | None = None,
sample_duration_hours: float | None = None,
warn: bool = True,
) -> ExposureResult

Daily noise exposure level from job-based measurements (ISO 9612:2009 Clause 10).

The effective-day level is the energy average of N >= 5 random job samples (Eq 11); the daily level follows Eq 12. The sampling uncertainty u1 is the sample standard deviation (Eq C.12) and its contribution c1*u1 is read from Table C.4; the combined uncertainty is Eq C.9 with c2 = c3 = 1.

Parameters

NameDescription
samplesMeasured Lp,A,eqT,n job samples, dB (at least five per Clause 10.2; a minimum of two is enforced numerically).
effective_duration_hoursEffective working-day duration T_e, hours.
instrumentInstrument class selecting u2 (Table C.5).
u3Microphone-position standard uncertainty, dB (Clause C.6 gives 1.0).
n_workersOptional homogeneous-group size n_G; when given with sample_duration_hours, the cumulative duration is checked against Table 1 and an advisory is raised if it falls short.
sample_duration_hoursOptional per-sample duration (hours) for the Table 1 cumulative-duration check.
warnEmit OccupationalExposureWarning for the Table C.4 / Table 1 advisories.

Returns: An ExposureResult.

minimum_cumulative_duration_hours(n_workers: int) -> float

Minimum cumulative measurement duration (h) for a homogeneous exposure group (Table 1).

Parameters

NameDescription
n_workersNumber of workers n_G in the homogeneous exposure group.

Returns: The minimum cumulative measurement duration in hours. For n_G > 40 the standard advises splitting the group; the returned 17 h is the tabulated fallback.

Advisory raised when an ISO 9612 sampling rule recommends more measurements.

table_c4_contribution(n_samples: int, u1: float) -> float

Uncertainty contribution c1*u1 (dB) from Table C.4 (job/full-day sampling).

Bilinear interpolation on the sample count N and the sampling standard uncertainty u1. The u1 axis is anchored at the origin (u1 = 0 gives 0 dB) and both axes are clamped to the tabulated range [3, 30] x [0, 6]. Rows N = 3 and N = 4 apply to full-day measurements only (ISO 9612:2009 Table C.4, NOTE 1).

Parameters

NameDescription
n_samplesNumber of job/full-day samples N (>= 2).
u1Standard uncertainty of the samples, dB (>= 0).

Returns: The contribution c1*u1 in dB.

Task(
samples: tuple[float, ...],
duration_hours: float,
duration_samples: tuple[float, ...] | None = None,
duration_range: tuple[float, float] | None = None,
label: str | None = None,
instrument: InstrumentClass | None = None,
)

One task of a task-based measurement (ISO 9612:2009 Clause 9).

Parameters

NameDescription
samplesMeasured Lp,A,eqT,mi levels for the task, dB. At least three are recommended (Clause 9.3); a single conservative value is allowed for negligible tasks (its u1a is then zero).
duration_hoursArithmetic mean task duration T_m (Eq 5), hours.
duration_samplesOptional independent duration observations T_m,j (hours) used for u1b via Eq C.7.
duration_rangeOptional (T_min, T_max) range (hours); u1b is then 0.5*(T_max - T_min) (Eq C.7 NOTE). Ignored if duration_samples is given.
labelOptional human-readable task name.
instrumentOptional per-task instrument class overriding the call default (selects u2 from Table C.5).
task_based_exposure(
tasks: Sequence[Task],
instrument: InstrumentClass = 'personal_exposimeter',
u3: float = 1.0,
include_duration_uncertainty: bool = True,
warn: bool = True,
) -> ExposureResult

Daily noise exposure level from task-based measurements (ISO 9612:2009 Clause 9).

Each task level is the energy average of its samples (Eq 7); the daily level is the energy sum of the task contributions (Eq 9/10). The uncertainty budget follows Eq C.3 with sampling u1a (Eq C.6), optional duration u1b (Eq C.7), and sensitivity coefficients c1a (Eq C.4) and c1b (Eq C.5).

Parameters

NameDescription
tasksThe tasks making up the nominal day.
instrumentDefault instrument class selecting u2 (Table C.5); may be overridden per Task.
u3Microphone-position standard uncertainty, dB (Clause C.6 gives 1.0).
include_duration_uncertaintyInclude the (c1b*u1b)^2 duration term (Eq C.3). When False the budget omits it (ISO 9612 Annex D case a).
warnEmit OccupationalExposureWarning when a task triggers the 3 dB spread rule (Clause 9.3).

Returns: An ExposureResult with per-task contributions.

TaskContribution(
label: str,
lp_aeqt: float,
duration_hours: float,
lex_8h_contribution: float,
n_samples: int,
sample_range_db: float,
spread_advisory: bool,
u1a: float,
c1a: float,
u1b: float,
c1b: float,
u2: float,
u3: float,
)

Per-task results and uncertainty terms of a task-based determination.

property

This task’s contribution to u^2(LEX,8h) (a term of Eq C.3), dB².