emission.declaration
Esta página aún no está disponible en tu idioma.
ISO 4871:1996 declaration of noise emission values of machinery and equipment.
ISO 4871 is the standardised noise-emission declaration: the information a manufacturer or supplier states in technical documents about the airborne noise emitted by a machine (clause 3.13). It does not measure anything itself; it prescribes which quantities are declared, in which of two alternative forms, and how a declared value is verified (clauses 4 to 6).
The quantities are the A-weighted sound power level L_WA (the preferred and
basic quantity, ISO 4871 Note 17) and, optionally, the A-weighted emission sound
pressure level L_pA at a work station (clause 3.11). Each is declared in one
of two forms selected by the relevant noise test code (clause 4):
- the dual-number form (clause 3.16): a measured noise emission value
Land its associated uncertaintyK, stated together but separately, both rounded to the nearest decibel; and - the single-number form (clause 3.15): the derived declared value
L_d, the sumL + Kof the unrounded quantities rounded once to the nearest decibel, an upper limit which values from repeated measurements are unlikely to exceed at the stated confidence level.
K combines the measurement uncertainty (reproducibility) and, for a batch,
the production spread (clauses 3.20 to 3.24; K = 1,645 sigma_R for a single
machine, Annex A.2.2). Verification (clause 6) compares a verification
measurement L_1 against the declared form: for a single machine the
combined form is verified when L_1 <= L_d and the dual-number form when
L_1 <= (L + K), the sum of the separately rounded declared values
(clause 6.2).
This module models a declaration as NoiseEmissionDeclaration, a set of
OperatingModeDeclaration values (one per operating mode, clause 4), and
renders it as an ISO 4871 declaration fiche through .report. A
declaration is most often built from a measured sound power via
declare.
Auto-generated from the source docstrings by
scripts/generate_api_docs.py(make api-docs). Do not edit by hand.
NoiseEmissionDeclaration
Section titled “NoiseEmissionDeclaration”NoiseEmissionDeclaration( modes: Sequence[OperatingModeDeclaration], machine: str | None = None, operating_conditions: str | None = None, noise_test_code: str | None = None, basic_standards: Sequence[str] = ..., form: DeclarationForm = 'dual-number',)An ISO 4871:1996 declaration of noise emission values (clauses 4 to 6).
A declaration is one or more OperatingModeDeclaration values (one
per operating mode, clause 4) plus the accompanying information required by
clause 5: identification of the machinery (clause 5 a), the noise test code
and basic standards used (clause 5 b) and the operating conditions
(clause 5 c). report renders it as a one-page ISO 4871 declaration
fiche.
Attributes
| Name | Description |
|---|---|
modes | One or more per-operating-mode declarations. A sequence is accepted and stored as a tuple. |
machine | Machine identification (model number and other identifying information, clause 5 a). |
operating_conditions | Operating and mounting conditions the values refer to (clause 5 c), e.g. "50 Hz, 230 V, rated load". |
noise_test_code | The noise test code the values were determined to (clause 5 b), e.g. an ISO family-specific test code; None when none exists. |
basic_standards | The basic noise-emission standard(s) used to obtain the values (clause 5 b), e.g. ("ISO 3744",). A single string is accepted and wrapped in a one-tuple. |
form | Which declaration form the fiche presents, "dual-number" (default, clause 3.16: L and K separately) or "single-number" (clause 3.15: the derived L_d = L + K). |
Raises
| Exception | When |
|---|---|
| ValueError | If no operating mode is given or form is unknown. |
NoiseEmissionDeclaration.report()
Section titled “NoiseEmissionDeclaration.report()”NoiseEmissionDeclaration.report( path: str, *, metadata: ReportMetadata | None = None, engine: str = 'reportlab', verbose: bool = False, language: str = 'en',) -> strRender an ISO 4871 noise-emission declaration fiche to a PDF.
Writes a one-page declaration data sheet: the standard-basis line
(ISO 4871:1996 and the cited basic emission standard), the machine
identification and operating conditions, the declared dual- or
single-number table across the operating-mode columns following the
ISO 4871 Annex B layouts (L_WA and K_WA for the dual-number
form, the derived L_WAd = L_WA + K_WA for the single-number form,
plus the emission sound pressure level when declared), the
noise-test-code and basic-standards footnote, a verification verdict
table when a verification measurement is supplied (clause 6.2, against
L_WAd for the single-number form or the separately rounded
L_WA + K_WA for the dual-number form), and the footer
identity/disclaimer block.
Parameters
| Name | Description |
|---|---|
path | Destination path of the PDF file. |
metadata | Optional ReportMetadata supplying the laboratory identity (footer) and, through measurement_standard, the basic emission standard shown in the standard-basis line when basic_standards is empty. |
engine | Rendering back end; only "reportlab" is supported. |
verbose | Accepted for a uniform .report() signature; the declaration fiche has a single table layout, so it has no effect. |
language | Fiche language: "en" (default, English) or "es" (Spanish, with a comma decimal separator). |
Returns: The written path as a str.
Raises
| Exception | When |
|---|---|
| ValueError | If engine is not "reportlab" or language is unknown. |
| ImportError | If reportlab is not installed (pip install phonometry[report]). |
OperatingModeDeclaration
Section titled “OperatingModeDeclaration”OperatingModeDeclaration( mode: str, sound_power_level: float, sound_power_uncertainty: float, emission_pressure_level: float | None = None, emission_pressure_uncertainty: float | None = None, verification_level: float | None = None,)Declared dual-number noise-emission values for one operating mode.
Holds the measured A-weighted sound power level L_WA and its uncertainty
K_WA (ISO 4871 clause 3.16), and optionally the A-weighted emission sound
pressure level L_pA at a work station with its uncertainty K_pA
(clause 3.11). The derived declared single-number values follow from
L_d = L + K (clause 3.15), the sum rounded to the nearest decibel. When a
verification measurement L_1 (an A-weighted sound power level determined
for verification, clause 6) is supplied, verified applies the
single-machine criterion of clause 6.2 for the combined form (verified when
L_1 <= L_WAd) and verified_dual the dual-number one (verified
when L_1 <= round(L_WA) + round(K_WA)).
Attributes
| Name | Description |
|---|---|
mode | Operating-mode label printed as the table column header (e.g. "Operating mode 1"); it identifies the operating mode of clause 5 c. |
sound_power_level | Measured mean A-weighted sound power level L_WA, in decibels re 1 pW. |
sound_power_uncertainty | Uncertainty K_WA of the sound power level, in decibels (finite and non-negative). |
emission_pressure_level | A-weighted emission sound pressure level L_pA at the work station, in decibels re 20 uPa; None when only the sound power level is declared. |
emission_pressure_uncertainty | Uncertainty K_pA of the emission sound pressure level, in decibels; required when emission_pressure_level is given and forbidden otherwise. |
verification_level | A verification measurement L_1 of the A-weighted sound power level (clause 6), in decibels; None when the mode is not verified. |
Raises
| Exception | When |
|---|---|
| ValueError | If a level is not finite, an uncertainty is not finite and non-negative, or only one member of the emission-pressure pair is given. |
OperatingModeDeclaration.declared_emission_pressure_level
Section titled “OperatingModeDeclaration.declared_emission_pressure_level”property
Declared single-number emission pressure level L_pAd = L_pA + K_pA.
The sum L_pA + K_pA rounded once to the nearest decibel (clause
3.15); None when no emission sound pressure level is declared for
the mode.
OperatingModeDeclaration.declared_sound_power_level
Section titled “OperatingModeDeclaration.declared_sound_power_level”property
Declared single-number sound power level L_WAd = L_WA + K_WA (3.15).
Clause 3.15 defines the declared value as the sum of the measured value and its uncertainty, rounded to the nearest decibel: the sum is formed from the unrounded quantities (clause 3.12) and rounded once, not assembled from the separately rounded dual-number values (3.16).
OperatingModeDeclaration.dual_number_verification_limit
Section titled “OperatingModeDeclaration.dual_number_verification_limit”property
Dual-number verification reference (L + K) (clauses 3.16, 6.2).
The dual-number form declares L and K each rounded to the
nearest decibel (clause 3.16), and clause 6.2 verifies that form
against their sum (L + K); the limit is therefore
round(L_WA) + round(K_WA) — not the single-number L_WAd
(the unrounded sum rounded once), which can differ by one decibel.
OperatingModeDeclaration.verified
Section titled “OperatingModeDeclaration.verified”property
Single-machine verification verdict, combined form (clause 6.2).
True when the verification measurement L_1 does not exceed the
combined (single-number) declared value L_WAd (L_1 <= L_WAd),
False otherwise, and None when no verification measurement is
supplied. For a dual-number declaration use verified_dual,
which compares against the separately rounded L + K.
OperatingModeDeclaration.verified_dual
Section titled “OperatingModeDeclaration.verified_dual”property
Single-machine verification verdict, dual-number form (clause 6.2).
True when the verification measurement L_1 does not exceed the
sum of the separately rounded declared values
(L_1 <= round(L_WA) + round(K_WA), clauses 3.16 and 6.2),
False otherwise, and None when no verification measurement is
supplied.