vibration.immission.vibration_meter

La referencia de la API se publica en inglés en los dos idiomas: se genera a partir de los docstrings del código, que son su texto original.

The vibration meter of DIN 45669-1:2010-09 (with Corrigendum 1:2012-12).

German immission control judges vibration in buildings with two standards that print thresholds and say almost nothing about how the number reaching them was formed: DIN 4150-2 for people in buildings and DIN 4150-3 for the buildings themselves. DIN 45669-1 is the missing half. It defines the instrument, and with it the quantities those thresholds are compared against, as exact transfer functions and exact time weightings, then grades a real meter against them.

The chain. A velocity signal is band-limited (5.2.3.2, Formula (3)), which is two Butterworth pairs: a two-pole high pass at and a two-pole low pass at . The working range is Hz to Hz for buildings, and 4 Hz to 315 Hz next to a railway, which is where DIN 45672-1 works. Frequency weighting (Formula (4)) divides that by , one more pole and one more zero, and normalising by 1 mm/s turns the result into the dimensionless KB signal. Its running r.m.s. with s (Formula (1)) is , the weighted vibration severity, and the quantities a meter displays are its maximum , the maximum within each 30 s clock interval (Takt) and the r.m.s. of those clock maxima (Formula (2)).

Two rules of Formula (2) that are easy to miss. A clock maximum at or below 0,1 enters the sum as zero but still counts in , so a quiet interval lowers the average rather than being dropped from it; and a clock interval that the measurement did not fill does not count at all (5.1.6.4), so the averaging time is always a whole number of clock intervals.

What Annex E adds. DIN 4150-3 compares a peak velocity with a guideline value that depends on frequency, so it needs a dominant frequency, and Annex D shows two ways of finding one that do not agree. Annex E removes the question: three weighting filters, one per building class of DIN 4150-3:1999-02 Table 1, each the inverse of that class’s guideline curve normalised to its 1 Hz to 10 Hz value. Filter the velocity with one of them and the peak of what comes out, the assessment velocity , is compared with a single number that no longer depends on frequency: 20, 5 or 3 mm/s (Table E.2). The filters are specified as a target magnitude with a % band and a linear phase, which is why this module designs them as symmetric FIRs.

Where the printed check values come from, and where one of them does not. Table 9 (folio 35) prints what a meter must display for a 1 mm/s sine at five frequencies, and its , and rows are reproduced by this module to the three decimals they are printed with, ripple and all. Its row is not, and cannot be: at 31,5 Hz it prints 1,000 where Formula (5) gives 0,995, and at 315 Hz it prints 0,249 where Formula (5) gives 0,100, while the row of the same column follows Formula (5) at both. The table contradicts itself rather than the formula, so KB_TEST_INDICATIONS carries the rows that agree with it and the other row is left to docs/ERRATA.md.

What a verdict here is and is not. verify_vibration_meter grades one thing, the amplitude response against Tables 2 and 3, which is Clause 5.2.3.3 of a standard whose Clause 6 also asks for linearity, overload, crest-factor handling, temperature, humidity and electromagnetic tests on hardware. Passing here is necessary for conformity and is not conformity.

Auto-generated from the source docstrings by scripts/generate_api_docs.py (make api-docs). Do not edit by hand.

assess_short_term_vibration(
velocity_mm_s: ArrayLike,
fs_hz: float,
*,
building_class: str,
numtaps: int | None = None,
) -> AssessmentVelocity

Judge short-term vibration on a building by Annex E.

Parameters

NameDescription
velocity_mm_sThe measured velocity at the foundation, in millimetres per second (1-D).
fs_hzSampling frequency, in hertz.
building_classSee assessment_weighting_response.
numtapsSee assessment_weighting_taps.

Returns: The comparison, as an AssessmentVelocity.

Raises

ExceptionWhen
ValueErrorFor a bad record, a rate below 630 Hz, or an unknown class.

Constant (mapping).

ASSESSMENT_GUIDE_VALUES_MM_S = {'commercial': 20.0, 'residential': 5.0, 'sensitive': 3.0}
assessment_velocity(
velocity_mm_s: ArrayLike,
fs_hz: float,
*,
building_class: str,
numtaps: int | None = None,
) -> NDArray[np.float64]

The assessment velocity v_Bn(t) of Annex E, in mm/s.

The velocity is filtered with the weighting of its building class and the constant delay of the symmetric filter is removed, so the result lines up in time with the record it came from.

Parameters

NameDescription
velocity_mm_sThe measured velocity, in millimetres per second (1-D). Annex E filters the unweighted signal, which has already been band-limited by 5.2.3.
fs_hzSampling frequency, in hertz.
building_classSee assessment_weighting_response.
numtapsSee assessment_weighting_taps.

Returns: v_Bn(t), one value per sample.

Raises

ExceptionWhen
ValueErrorFor a bad record, a rate below 630 Hz, or an unknown class.
assessment_weighting_response(
frequencies_hz: ArrayLike,
*,
building_class: str,
) -> NDArray[np.float64]

The target magnitude of an Annex E weighting filter, Table E.1.

Each filter is the guideline curve of its building class inverted and normalised to the value that curve holds from 1 Hz to 10 Hz, so filtering with it turns a frequency-dependent comparison into a comparison with one number. The curve is flat below 10 Hz, rises along two straight segments to 100 Hz and is flat above it, and Table E.1 carries that last segment up to the Nyquist frequency rather than stopping at 100 Hz.

Parameters

NameDescription
frequencies_hzFrequencies, in hertz.
building_classThe row of DIN 4150-3:1999-02 Table 1, as ASSESSMENT_GUIDE_VALUES_MM_S keys it.

Returns: The target magnitude, dimensionless, 1 below 10 Hz.

Raises

ExceptionWhen
ValueErrorFor a non-positive frequency or an unknown class.
assessment_weighting_taps(
fs_hz: float,
*,
building_class: str,
numtaps: int | None = None,
) -> NDArray[np.float64]

A linear-phase FIR that realises an Annex E weighting.

Annex E asks for a linear phase and says why: a weighting filter that delays different frequencies differently changes the peak it is there to measure. A symmetric FIR is the type the annex names, and its only cost is a constant delay of half its length, which assessment_velocity removes.

Parameters

NameDescription
fs_hzSampling frequency, in hertz. Table E.1 requires the Nyquist frequency to be above 315 Hz where the meter reaches that far, and this refuses a rate below 630 Hz for the same reason.
building_classSee assessment_weighting_response.
numtapsLength of the filter, odd. The default resolves the 10 Hz corner of the target with room to spare, at half a second of taps.

Returns: The filter coefficients.

Raises

ExceptionWhen
ValueErrorFor a rate below 630 Hz, an even or non-positive length, or an unknown class.

Constant (float).

ASSESSMENT_WEIGHTING_TOLERANCE = 0.05
AssessmentVelocity(
assessment_velocity_mm_s: float,
guide_value_mm_s: float,
building_class: str,
velocity_mm_s: NDArray[np.float64],
fs_hz: float,
)

One record judged by Annex E, without a dominant frequency.

Attributes

NameDescription
assessment_velocity_mm_s, the peak of the weighted velocity, in millimetres per second.
guide_value_mm_sThe Table E.2 value it is compared with.
building_classThe row of DIN 4150-3 Table 1 that was used.
velocity_mm_sThe weighted velocity itself, one value per sample.
fs_hzThe sampling frequency the record was read at.
AssessmentVelocity.plot(
ax: Axes | None = None,
*,
language: str = 'en',
**kwargs: Any,
) -> Axes

Draw the weighted velocity against its guideline value.

Requires matplotlib (pip install phonometry[plot]); returns the Axes.

Parameters

NameDescription
axExisting axes, or None to create a figure.
languageLabel language, "en" (default) or "es".
kwargsForwarded to phonometry._plot.vibration.plot_assessment_velocity.

property

The peak as a fraction of the guideline value.

property

Whether the record keeps to the guideline value of Table E.2.

The same reading as DIN 4150-3 gives it: keeping to the value is what the standard promises about, exceeding it means the question moves to Clauses 4.2 to 4.4 rather than that damage has occurred.

Constant (float).

BAND_LIMIT_CORNER_FACTOR = 0.8
band_limitation_response(
frequencies_hz: ArrayLike,
*,
working_range: str = 'building',
) -> NDArray[np.complex128]

The band limitation of the unweighted signal, Formula (3).

Parameters

NameDescription
frequencies_hzFrequencies, in hertz.
working_range"building" (1 Hz to 80 Hz, the default) or "railway" (4 Hz to 315 Hz); see WORKING_RANGES_HZ.

Returns: The complex response , whose magnitude is Formula (5).

Raises

ExceptionWhen
ValueErrorFor a non-positive frequency or an unknown range.
dominant_frequency(
velocity_mm_s: ArrayLike,
fs_hz: float,
*,
method: Literal['zero_crossing', 'fourier'] | str = 'zero_crossing',
) -> DominantFrequency

The dominant frequency of a short-term event, by one of Annex D’s ways.

A short-term vibration has no frequency in the physical sense, and Annex D says so before giving two ways of naming one anyway. They can disagree, and the disagreement matters: the frequency picks the guideline value in DIN 4150-3, so it can change the verdict. That is the ambiguity Annex E removes, and this function is here for the case where the frequency itself has to be reported.

Parameters

NameDescription
velocity_mm_sThe measured velocity, in millimetres per second (1-D).
fs_hzSampling frequency, in hertz.
method"zero_crossing" (D a), the default: the two zero crossings around the largest amplitude are half a period apart) or "fourier" (D b): the largest value of the spectrum of the whole event, with the runner-up reported beside it.

Returns: The frequency and how it was found, as a DominantFrequency.

Raises

ExceptionWhen
ValueErrorFor a bad record, a non-positive rate, an unknown method, or a record whose largest amplitude has no zero crossing on both sides of it.
DominantFrequency(
frequency_hz: float,
method: str,
candidates: tuple[tuple[float, float], ...],
)

The dominant frequency of one event, and how it was found (Annex D).

Attributes

NameDescription
frequency_hzThe dominant frequency, in hertz.
method"zero_crossing" or "fourier".
candidatesFor the Fourier method, the two largest spectral values as (frequency in hertz, magnitude) pairs, largest first, which is what D b) asks a meter to report so the choice between them is made rather than assumed. Empty for the zero-crossing method.

Constant (float).

KB_CORNER_HZ = 5.6

Constant (float).

KB_DETECTION_LIMIT = 0.02

Constant (float).

KB_INDICATION_TOLERANCE_PERCENT = 4.0

Constant (tuple).

KB_PULSE_RESPONSE_PERCENT = ((inf, 80, 100.4), (800.0, 64, 100.3), (400.0, 32, 98.3), (200.0, 16, 89.7), (100.0, 8, 74.5), (50.0, 4, 57.6), (25.0, 2, 42.7), (12.5, 1, 30.9))

Constant (float).

KB_REFERENCE_FREQUENCY_HZ = 16.0

Constant (mapping).

KB_REFERENCE_INDICATIONS = {'peak_velocity_mm_s': 1.0, 'kbf': 0.667, 'kbf_max': 0.68, 'kbf_takt_rms': 0.68}
kb_signal(
velocity_mm_s: ArrayLike,
fs_hz: float,
*,
working_range: str = 'building',
) -> NDArray[np.float64]

The KB signal KB(t) of 3.10.1.1, which is dimensionless.

The velocity is band-limited and frequency-weighted by Formula (4) and normalised by 1 mm/s, which is the normalisation that makes the KB signal a number rather than a velocity, so the record has to be in millimetres per second for the result to mean what the standard says.

Parameters

NameDescription
velocity_mm_sThe measured velocity, in millimetres per second (1-D).
fs_hzSampling frequency, in hertz.
working_rangeSee band_limitation_response.

Returns: KB(t), one value per sample.

Raises

ExceptionWhen
ValueErrorFor a bad record, a rate that cannot carry the working range, or an unknown range.

Constant (mapping).

KB_TEST_INDICATIONS = {1.0: (0.103, 0.13, 0.13), 5.6: (0.5, 0.528, 0.528), 31.5: (0.693, 0.7, 0.7), 80.0: (0.594, 0.597, 0.597), 315.0: (0.071, 0.071, 0.071)}

Constant (float).

KB_TIME_CONSTANT_S = 0.125
kb_weighting_response(
frequencies_hz: ArrayLike,
*,
working_range: str = 'building',
) -> NDArray[np.complex128]

The KB frequency weighting, Formula (4).

Parameters

NameDescription
frequencies_hzFrequencies, in hertz.
working_rangeSee band_limitation_response.

Returns: The complex response , whose magnitude is Formula (6).

Raises

ExceptionWhen
ValueErrorFor a non-positive frequency or an unknown range.
kbf_signal(
velocity_mm_s: ArrayLike,
fs_hz: float,
*,
working_range: str = 'building',
time_constant_s: float = 0.125,
) -> NDArray[np.float64]

The weighted vibration severity KB_F(t), Formula (1).

The running r.m.s. is the exponential average the formula integrates, as the single-pole recursion Annex A draws: y[i] = (1 - a) y[i-1] + a x[i] with a = 1 - exp(-1 / (tau fs)). It starts from zero, so the first samples ramp up like a meter switched on with the signal already present; 2 tau of record is 14 % low in mean square and 4 tau is 2 % low, which is why a measurement is started before the event it is about.

Parameters

NameDescription
velocity_mm_sThe measured velocity, in millimetres per second (1-D).
fs_hzSampling frequency, in hertz.
working_rangeSee band_limitation_response.
time_constant_sThe averaging time constant, in seconds. The standard fixes it at 0,125 s and the parameter exists so a comparison with another time weighting can be written down, not so a meter can use one.

Returns: KB_F(t), one value per sample.

Raises

ExceptionWhen
ValueErrorFor a bad record, a non-positive time constant, or a rate that cannot carry the working range.
measure_vibration_immission(
velocity_mm_s: ArrayLike,
fs_hz: float,
*,
working_range: str = 'building',
takt_duration_s: float = 30.0,
) -> VibrationMeterReading

Run one velocity record through the whole chain of 5.1.6.

Start the record before the event. Every filter here begins at rest, so a record that begins with the signal already at full amplitude carries the filter’s own switch-on transient, and the peak is a max-hold that keeps it: a 1 mm/s sine started at a zero crossing reads 1,06 mm/s rather than the 1,00 mm/s of 6.2.3.12, and at 315 Hz outside the building range it reads 0,25 mm/s where the steady response is 0,10 mm/s. That is an artefact of the record, not of the chain, and a lead-in of a second or two of quiet removes it, which is also how a real measurement is made.

Parameters

NameDescription
velocity_mm_sThe measured velocity, in millimetres per second (1-D).
fs_hzSampling frequency, in hertz.
working_rangeSee band_limitation_response.
takt_duration_sThe clock interval, in seconds (default 30 s).

Returns: The displayed quantities, as a VibrationMeterReading.

Raises

ExceptionWhen
ValueErrorFor a bad record, a rate that cannot carry the working range, or a non-positive clock interval.

Constant (tuple).

RESPONSE_TOLERANCE_LOWER_PERCENT = ((1.25, 0.8, 10.0), (0.5, 2.0, 20.0))
response_tolerance_percent(
frequencies_hz: ArrayLike,
*,
working_range: str = 'building',
) -> tuple[NDArray[np.float64], NDArray[np.float64]]

The limits of Tables 2 and 3 at each frequency, in per cent.

Parameters

NameDescription
frequencies_hzFrequencies, in hertz.
working_rangeSee band_limitation_response.

Returns: (lower, upper): the largest deviation allowed below and above the design response, both as positive percentages. A lower limit of 100 % is the standard declining to constrain the response from below outside the working range.

Raises

ExceptionWhen
ValueErrorFor a non-positive frequency or an unknown range.

Constant (tuple).

RESPONSE_TOLERANCE_UPPER_PERCENT = ((1.25, 0.8, 10.0), (0.0, inf, 20.0))

Constant (float).

TAKT_DURATION_S = 30.0
takt_maxima(
kbf: ArrayLike,
fs_hz: float,
*,
takt_duration_s: float = 30.0,
) -> NDArray[np.float64]

The clock maxima KB_FTi of 3.10.1.4, one per whole clock interval.

A clock interval the record did not fill is not a clock interval: 5.1.6.4 says the averaging time always spans a whole number of them, so a trailing part-interval is dropped rather than scaled up.

Parameters

NameDescription
kbfThe KB_F(t) signal (1-D).
fs_hzSampling frequency, in hertz.
takt_duration_sThe clock interval, in seconds (default 30 s).

Returns: One maximum per whole clock interval, in order. Empty when the record is shorter than one interval.

Raises

ExceptionWhen
ValueErrorFor a bad signal or a non-positive rate or interval.
takt_maximum_rms(maxima: ArrayLike) -> float

The clock maximum r.m.s. KB_FTm, Formula (2).

Both rules of the formula are here: a clock maximum at or below TAKT_SUPPRESSION_THRESHOLD enters the sum as zero, and the interval it came from still counts in N, so a run of quiet intervals pulls the result down instead of leaving it unchanged.

Parameters

NameDescription
maximaThe clock maxima of takt_maxima.

Returns: KB_FTm, dimensionless. Zero for an empty input, which is the answer for a record with no whole clock interval in it.

Raises

ExceptionWhen
ValueErrorIf a maximum is negative or not finite.

Constant (float).

TAKT_SUPPRESSION_THRESHOLD = 0.1

Constant (float).

VELOCITY_DETECTION_LIMIT_MM_S = 0.05
verify_vibration_meter(
frequencies_hz: ArrayLike,
measured_response: ArrayLike,
*,
weighting: Literal['kb', 'unweighted'] | str = 'kb',
working_range: str = 'building',
reference_frequency_hz: float = 16.0,
) -> VibrationMeterVerification

Verify a measured amplitude response against Tables 2 and 3.

Formula (7) is a ratio of ratios: the measured response over the design response, each divided by its own value at the reference frequency, so a meter is graded on the shape of its response and not on the gain that a calibration sets. The reference frequency itself carries no requirement, the standard writing every limit “for all f not equal to f_r”, and it is dropped from the verdict rather than passed for free.

Parameters

NameDescription
frequencies_hzThe frequencies the response was measured at, in hertz. The reference frequency has to be among them.
measured_responseThe measured amplitude response at those frequencies, in any consistent unit: only its shape is graded.
weighting"kb" for the weighted response of Formula (4), the default, or "unweighted" for the band limitation of Formula (3).
working_rangeSee band_limitation_response.
reference_frequency_hzThe reference frequency of 5.2.10, in hertz (default 16 Hz).

Returns: The comparison, as a VibrationMeterVerification.

Raises

ExceptionWhen
ValueErrorIf the two arrays disagree in shape, if a frequency or a response is not positive and finite, or if the reference frequency is not one of the measured frequencies.
VibrationMeterReading(
peak_velocity_mm_s: float,
kbf: NDArray[np.float64],
kbf_max: float,
takt_maxima: NDArray[np.float64],
kbf_takt_rms: float,
fs_hz: float,
measuring_time_s: float,
averaging_time_s: float,
working_range: str,
)

What a meter displays for one record (5.1.6.1).

Attributes

NameDescription
peak_velocity_mm_s, the largest absolute value of the band-limited velocity over the measuring time.
kbfThe KB_F(t) signal, one value per sample.
kbf_max, its maximum.
takt_maximaThe clock maxima, one per whole clock interval.
kbf_takt_rms of Formula (2).
fs_hzThe sampling frequency the record was read at.
measuring_time_s, the length of the record.
averaging_time_s, the whole clock intervals in it.
working_rangeThe working range the chain was built for.

VibrationMeterReading.above_detection_limit

Section titled “VibrationMeterReading.above_detection_limit”

property

Whether the reading is above the detection limits of 5.2.2.

Below them a meter is not required to resolve anything, so a smaller reading is not a measurement of a smaller vibration.

VibrationMeterReading.plot(
ax: Axes | None = None,
*,
language: str = 'en',
**kwargs: Any,
) -> Axes

Draw KB_F(t) with its maximum and the clock maxima on it.

Requires matplotlib (pip install phonometry[plot]); returns the Axes.

Parameters

NameDescription
axExisting axes, or None to create a figure.
languageLabel language, "en" (default) or "es".
kwargsForwarded to phonometry._plot.vibration.plot_vibration_meter_reading.
VibrationMeterVerification(
frequencies_hz: NDArray[np.float64],
deviation_percent: NDArray[np.float64],
lower_percent: NDArray[np.float64],
upper_percent: NDArray[np.float64],
within_tolerance: NDArray[np.bool_],
weighting: str,
working_range: str,
reference_frequency_hz: float,
)

One measured amplitude response against Tables 2 and 3.

Attributes

NameDescription
frequencies_hzThe frequencies the response was measured at.
deviation_percentF(f) of Formula (7) at each of them: the measured response over the design response, both normalised at the reference frequency, as a percentage departure from unity.
lower_percentThe Table 2 limit at each frequency.
upper_percentThe Table 3 limit at each frequency.
within_toleranceWhether each frequency keeps to both limits.
weighting"kb" or "unweighted", which design response the deviation is against.
working_rangeThe working range the limits were read for.
reference_frequency_hzThe frequency both responses were normalised at.

property

Whether every graded frequency keeps to its limits.

VibrationMeterVerification.plot(
ax: Axes | None = None,
*,
language: str = 'en',
**kwargs: Any,
) -> Axes

Draw the deviation against the tolerance band it is judged by.

Requires matplotlib (pip install phonometry[plot]); returns the Axes.

Parameters

NameDescription
axExisting axes, or None to create a figure.
languageLabel language, "en" (default) or "es".
kwargsForwarded to phonometry._plot.vibration.plot_vibration_meter_verification.

VibrationMeterVerification.worst_frequency_hz

Section titled “VibrationMeterVerification.worst_frequency_hz”

property

The frequency that uses the largest share of its allowance.

Constant (mapping).

WORKING_RANGES_HZ = {'building': (1.0, 80.0), 'railway': (4.0, 315.0)}