Atmospheric absorption of sound: ISO 9613-1:1993.
The attenuation of a pure tone propagating through the atmosphere is governed by
a pure-tone attenuation coefficient alpha (in dB/m) that depends on frequency,
temperature, humidity and pressure through the vibrational relaxation of the
oxygen and nitrogen molecules plus classical and rotational losses
(ISO 9613-1:1993, clause 6).
The attenuation coefficient (ISO 9613-1:1993, Eq. (5)):
alpha = 8,686 * f^2 * { 1,84e-11 * (pa/pr)^-1 * (T/T0)^(1/2) + (T/T0)^(-5/2) * [ 0,012 75 * exp(-2239,1/T) * (frO + f^2/frO)^-1 + 0,106 8 * exp(-3352,0/T) * (frN + f^2/frN)^-1 ] }in decibels per metre, with the oxygen and nitrogen relaxation frequencies (ISO 9613-1:1993, Eq. (3) and Eq. (4)):
frO = (pa/pr) * [24 + 4,04e4 * h * (0,02 + h)/(0,391 + h)]frN = (pa/pr) * (T/T0)^(-1/2) * [9 + 280 * h * exp{-4,170 * [(T/T0)^(-1/3) - 1]}]Here T is the ambient temperature (K), T0 = 293,15 K and
pr = 101,325 kPa are the reference conditions (ISO 9613-1:1993, clause 4.2),
pa is the ambient pressure (kPa) and h is the molar concentration of
water vapour as a percentage, obtained from the relative humidity by the
psychrometric conversion (ISO 9613-1:1993, clause 6.4 / Annex B):
h = hr * (psat/pr) / (pa/pr)psat/pr = 10 ^ (-6,8346 * (T01/T)^1,261 + 4,6151), T01 = 273,16 Kwith hr the relative humidity (%) and T01 the triple-point temperature of
water.
Table 1 of ISO 9613-1:1993 tabulates alpha (in dB/km) at the reference
pressure for a grid of temperature, relative humidity and one-third-octave
frequency; its rows are labelled with the ISO 266 preferred frequencies but the
coefficients are computed at the exact midband frequencies (Note 5)
fm = 1000 * 10^(k/10), k integer. Pass exact_midband=True to snap the
requested frequencies onto that grid and reproduce Table 1 exactly.
This module closes the loop with phonometry.sound_absorption (ISO 354),
whose air power-attenuation coefficient m (1/m) is defined only through the
ISO 9613-1 alpha via m = alpha / (10 * lg e). air_attenuation_m
returns that m directly.
Auto-generated from the source docstrings by
scripts/generate_api_docs.py(make api-docs). Do not edit by hand.
air_attenuation
Section titled “air_attenuation”air_attenuation( frequencies: ArrayLike, temperature: float = 20.0, relative_humidity: float = 50.0, pressure: float = 101.325, *, exact_midband: bool = False,) -> NDArray[np.float64]Pure-tone atmospheric attenuation coefficient (ISO 9613-1:1993, Eq. (5)).
Evaluates alpha in decibels per metre from the oxygen and nitrogen
relaxation frequencies (Eq. (3)/(4)) and the classical, rotational and
vibrational absorption terms (Eq. (5)). Fully vectorized over
frequencies; temperature, relative_humidity and pressure are
scalars.
Parameters
| Name | Description |
|---|---|
frequencies | Frequency or frequencies f, in hertz (array-like). |
temperature | Ambient air temperature, in degrees Celsius (default 20 degC, i.e. the reference T0). A value outside the -20..+50 degC tabulated range emits an AtmosphericAbsorptionWarning; a value at or below absolute zero raises ValueError. |
relative_humidity | Relative humidity, in percent, with respect to saturation over liquid water (default 50 %). Outside 10..100 % emits an AtmosphericAbsorptionWarning; outside [0, 100] % raises ValueError. |
pressure | Ambient atmospheric pressure pa, in kilopascals (default 101,325 kPa = one standard atmosphere = pr). Above 200 kPa emits an AtmosphericAbsorptionWarning; non-positive raises ValueError. |
exact_midband | When True, each requested frequency is snapped to the nearest exact one-third-octave midband fm = 1000*10^(k/10) (Eq. (6)) before evaluation, reproducing the frequencies used for Table 1 (Note 5). Default False (use frequencies verbatim). |
Returns: Attenuation coefficient alpha, in dB/m, with the shape of frequencies.
air_attenuation_m
Section titled “air_attenuation_m”air_attenuation_m( frequencies: ArrayLike, temperature: float = 20.0, relative_humidity: float = 50.0, pressure: float = 101.325, *, exact_midband: bool = False,) -> NDArray[np.float64]ISO 354 air power-attenuation coefficient m (1/m) from conditions.
Convenience composition of air_attenuation (ISO 9613-1 alpha in
dB/m) with the ISO 354:2003 (8.1.2.1) conversion m = alpha / (10 * lg e)
(via phonometry.sound_absorption.attenuation_from_alpha). It lets an
ISO 354 caller feed real atmospheric conditions into
absorption_area /
absorption_coefficient instead of
hand-entering m.
Parameters
| Name | Description |
|---|---|
frequencies | Frequency or frequencies f, in hertz (array-like). |
temperature | Ambient air temperature, in degrees Celsius (default 20). |
relative_humidity | Relative humidity, in percent (default 50). |
pressure | Ambient atmospheric pressure, in kilopascals (default 101,325). |
exact_midband | Snap frequencies to exact midbands; see air_attenuation. |
Returns: Power attenuation coefficient m, in 1/m, with the shape of frequencies.
atmospheric_attenuation
Section titled “atmospheric_attenuation”atmospheric_attenuation( frequencies: ArrayLike, temperature: float = 20.0, relative_humidity: float = 50.0, pressure: float = 101.325, *, exact_midband: bool = False, distance: float | None = None,) -> AtmosphericAttenuationBuild a plottable ISO 9613-1 atmospheric-attenuation curve.
Evaluates air_attenuation at frequencies for the given
atmospheric conditions and bundles the result into an
AtmosphericAttenuation that exposes .plot(). The maths is
unchanged; this is a thin, plottable wrapper around the existing function
(the same warnings and the same ValueError cases apply).
Parameters
| Name | Description |
|---|---|
frequencies | Frequency or frequencies f, in hertz (array-like). |
temperature | Ambient air temperature, in degrees Celsius (default 20). |
relative_humidity | Relative humidity, in percent (default 50). |
pressure | Ambient atmospheric pressure, in kilopascals (default 101.325 kPa, one standard atmosphere). |
exact_midband | Snap the frequencies to the exact one-third-octave midbands fm = 1000*10^(k/10) (Eq. (6)) before evaluation; see air_attenuation. When True the stored frequencies are the snapped midbands the coefficient was computed at. |
distance | Optional propagation distance d, in metres. When given, the result’s total_attenuation returns the total attenuation A = alpha * d over that distance (ISO 9613-2 Eq. (8)). Must be finite and non-negative. |
Returns: A frozen AtmosphericAttenuation.
Raises
| Exception | When |
|---|---|
| ValueError | If distance is negative or non-finite (NaN/inf); the check lives on AtmosphericAttenuation so it also guards direct construction. |
AtmosphericAbsorptionWarning
Section titled “AtmosphericAbsorptionWarning”Advisory for ISO 9613-1 inputs outside the tabulated/validity ranges.
AtmosphericAttenuation
Section titled “AtmosphericAttenuation”AtmosphericAttenuation( frequencies: NDArray[np.float64], attenuation_coefficient: NDArray[np.float64], temperature: float, relative_humidity: float, pressure: float, distance: float | None = None,)A pure-tone atmospheric attenuation curve (ISO 9613-1:1993).
Bundles the ISO 9613-1 attenuation coefficient alpha (Eq. (5)) over a
frequency grid with the atmospheric conditions it was evaluated for, so the
classic alpha versus frequency curve can be drawn with plot.
Build it with atmospheric_attenuation; the frozen instance is a thin,
plottable wrapper and re-runs none of the maths.
Attributes
| Name | Description |
|---|---|
frequencies | Frequencies f the coefficient is evaluated at, in Hz (the exact one-third-octave midbands when exact_midband was used). |
attenuation_coefficient | Pure-tone attenuation coefficient alpha, per frequency, in decibels per metre (Table 1 prints dB/km, i.e. x 1000). |
temperature | Ambient air temperature, in degrees Celsius. |
relative_humidity | Relative humidity, in percent. |
pressure | Ambient atmospheric pressure pa, in kilopascals. |
distance | Propagation distance d, in metres, or None when the result carries only the coefficient. When given, total_attenuation returns the total attenuation A = alpha * d over that distance. |
AtmosphericAttenuation.plot()
Section titled “AtmosphericAttenuation.plot()”AtmosphericAttenuation.plot( ax: Axes | None = None, *, language: str = 'en', **kwargs: Any,) -> AxesPlot the attenuation coefficient alpha versus frequency.
Draws alpha (in dB/km, as Table 1 tabulates it) on a logarithmic
frequency axis, the classic ISO 9613-1 curve for the stored atmospheric
conditions. Requires matplotlib (pip install phonometry[plot]);
returns the Axes and never calls plt.show.
Parameters
| Name | Description |
|---|---|
ax | Existing axes, or None to create a figure. |
language | "en" (default) or "es". |
kwargs | Forwarded to the alpha curve plot call. |
Returns: The axes.
AtmosphericAttenuation.total_attenuation
Section titled “AtmosphericAttenuation.total_attenuation”property
Total atmospheric attenuation A = alpha * d over distance.
The pure-tone attenuation alpha (dB/m) accumulated over the
propagation distance d (m), per frequency, in decibels; this is the
ISO 9613-2:1996 Aatm (Eq. (8)) form. None when no
distance was supplied.