The exponential-sweep test of a band filter: time-invariant operation.

IEC 61260-1:2014 5.14 asks a set of filters that claims time-invariant operation to pass a test a transfer function cannot: driven by a constant-amplitude sinusoid whose frequency rises at an exponential rate, each filter’s time-averaged output shall stay within dB (class 1) or dB (class 2) of the level Formula (17) predicts,

for a sweep of one decade in 2 s to 5 s (5.14.3). Annex G derives it: the time average of the swept output is the effective bandwidth over the sweep rate, so a filter whose effective bandwidth is the reference one () reads exactly (G.2.8). IEC 61260-2:2016 7.4 is the pattern-evaluation test and IEC 61260-3:2016 10.3 uses the same sweep to measure the effective bandwidth deviation of a time-invariant filter in a periodic test.

This module has three things for it:

  • swept_band_level, Formula (17) itself, which IEC 61260-2 and -3 Annex B work through to dB;
  • swept_level_uncertainty, the standard uncertainty of that level from the uncertainties of the sweep (Annex A of IEC 61260-2 and -3, Formula (A.2)); the annexes print dB for their example, which this reproduces, while the printed Formula (A.2) drops the square on the coefficient of its frequency terms (see the errata registry);
  • verify_time_invariance, the test run on an OctaveFilterBank: the sweep of Formulas (A.3) and (A.4) goes through every band exactly as the bank filters a signal, the polyphase decimation of a multirate bank included, so it tests what the transfer functions alone cannot.

Auto-generated from the source docstrings by scripts/generate_api_docs.py (make api-docs). Do not edit by hand.

swept_band_level(
input_level_db: float,
*,
fraction: float,
sweep_duration_s: float,
averaging_time_s: float,
start_frequency_hz: float,
end_frequency_hz: float,
reference_attenuation_db: float = 0.0,
) -> float

IEC 61260-1:2014 Formula (17): the time-averaged output of a sweep.

with for a base-ten filter of bandwidth designator (NOTE 1 to 5.14.2): the level an exponential sweep of constant amplitude leaves, averaged over , at the output of a filter whose relative attenuation is zero in its pass band and infinite outside it (NOTE 2). The deviation of a measured output from it is what 5.14.3 and IEC 61260-3:2016 10.3.6 grade.

Parameters

NameDescription
input_level_db, the level of the sweep.
fractionThe bandwidth designator denominator b.
sweep_duration_s, the time from the start frequency to the end frequency.
averaging_time_s, the averaging time of the output level.
start_frequency_hz.
end_frequency_hz, above the start.
reference_attenuation_db, the reference attenuation of 5.9 (0 dB by default).

Returns: in the unit of input_level_db.

Raises

ExceptionWhen
ValueErrorfor a non-positive bandwidth designator, duration, averaging time or frequency, or an end frequency not above the start.
swept_level_uncertainty(
*,
input_level_uncertainty_db: float,
sweep_duration_s: float,
sweep_duration_uncertainty_s: float,
averaging_time_s: float,
averaging_time_uncertainty_s: float,
start_frequency_hz: float,
start_frequency_uncertainty_hz: float,
end_frequency_hz: float,
end_frequency_uncertainty_hz: float,
display_resolution_db: float = 0.0,
) -> float

The standard uncertainty of swept_band_level, from the sweep.

Annex A of IEC 61260-2:2016 and of IEC 61260-3:2016 propagates the standard uncertainties of the input level, the sweep time, the averaging time and the two end frequencies through Formula (17) (A.1):

Formula (A.2) as printed in both parts leaves the square off the coefficient of the frequency terms; the square is what the derivative of Formula (17) gives, and it is the only reading that reproduces the annexes’ own example (A.3.5): dB and an expanded uncertainty of 0.115 dB, where the printed form gives 0.075 dB. See the errata registry.

A reading taken from a display adds its resolution as a rectangular distribution of half-width half the resolution (IEC 61260-3:2016 5.2): display_resolution_db=0.1 turns the example’s 0.115 dB into the 0.128 dB of A.3.5.

Parameters

NameDescription
input_level_uncertainty_db, standard.
sweep_duration_s.
sweep_duration_uncertainty_sIts standard uncertainty.
averaging_time_s.
averaging_time_uncertainty_sIts standard uncertainty.
start_frequency_hz.
start_frequency_uncertainty_hzIts standard uncertainty.
end_frequency_hz, above the start.
end_frequency_uncertainty_hzIts standard uncertainty.
display_resolution_dbThe resolution of the display the output level is read from, 0 when it is not read from one.

Returns: , the standard uncertainty in dB; the annexes expand it with a coverage factor of 2.

Raises

ExceptionWhen
ValueErrorfor a negative uncertainty or resolution, a non-positive duration or frequency, or an end frequency not above the start.
TimeInvarianceResult(
band_frequencies: np.ndarray,
fraction: float,
fs: float,
seconds_per_decade: tuple[float, ...],
start_frequency_hz: float,
end_frequency_hz: float,
sweep_durations_s: tuple[float, ...],
averaging_times_s: tuple[float, ...],
output_levels_db: np.ndarray,
expected_levels_db: np.ndarray,
)

The time-invariance verdict of a filter bank, IEC 61260-1:2014 5.14.

What verify_time_invariance returns. For every sweep rate and every band it holds the time-averaged output level of the bank driven by an exponential sweep and the level Formula (17) predicts for it,

whose difference 5.14.3 bounds by dB for class 1 and dB for class 2. The levels are in decibels relative to the level of the input sweep, whose effective value is 1 (IEC 61260-2 Formula (A.4)), so dB.

Attributes

NameDescription
band_frequenciesThe exact mid-band frequencies, Hz.
fractionThe bandwidth designator denominator b.
fsThe bank’s sampling rate, Hz.
seconds_per_decadeThe sweep rates, one decade in so many seconds.
start_frequency_hz of every sweep.
end_frequency_hz of every sweep.
sweep_durations_s, one per rate.
averaging_times_s, one per rate: the sweep and the silence after it during which the slowest band’s output dies away.
output_levels_dbThe measured time-averaged output level , shape (rates, bands).
expected_levels_db of Formula (17), same shape.

property

The strictest class each band meets at every sweep rate.

property

, shape (rates, bands).

property

The strictest class every band meets, None if one meets none.

TimeInvarianceResult.plot(
ax: Axes | None = None,
*,
language: str = 'en',
**kwargs: Any,
) -> Axes

Plot every band’s deviation from Formula (17), one line per rate.

Requires matplotlib (pip install phonometry[plot]); returns the Axes.

Parameters

NameDescription
axExisting axes, or None to create a figure.
languageLabel language, "en" (default) or "es".
kwargsForwarded to phonometry._plot.filters.plot_time_invariance.

property

The deviation of largest magnitude, signed, over bands and rates.

verify_time_invariance(
bank: OctaveFilterBank,
*,
seconds_per_decade: tuple[float, ...] = (2.0, 5.0),
) -> TimeInvarianceResult

Test the time-invariant operation of a bank, IEC 61260-1:2014 5.14.

The swept-frequency test of IEC 61260-2:2016 7.4, run on the bank itself: an exponential sweep of effective value 1 (Formulas (A.3) and (A.4)) goes through every band exactly as OctaveFilterBank.filter processes it, the polyphase decimation of a multirate bank included, and each band’s time-averaged output is compared with the level of Formula (17). A bank whose bands do what their transfer functions say reads, band by band, its effective bandwidth deviation (Annex G, G.2.8); decimation that folds energy back into a band, or state that is not carried from one sample to the next, reads as more.

  • The sweep starts one decade below the frequency at which the lowest band’s relative attenuation reaches 55 dB below its lower band edge, and ends one decade above the matching point of the highest band, or at the Nyquist frequency if that comes first (7.4.2 asks for “at least” 55 dB; the extra decade keeps the start transient of the sweep out of the lowest band).
  • The averaging runs from the start of the sweep until the slowest band’s impulse response has lost all but of its energy after the sweep ends (7.4.4).
  • The reference attenuation is each band’s attenuation at its exact mid-band frequency, as verify_filter_class takes it.

A time-invariant design is an optional claim: 5.14.4 has the instruction manual state the bandwidths and frequency ranges it applies to, and the verdict here is for the bank as configured.

Parameters

NameDescription
bankThe filter bank; its designed sections and decimation factors are run, and a stateful bank’s carried state is left alone.
seconds_per_decadeThe sweep rates to run, one decade in so many seconds, each within the 2 s to 5 s for which 5.14.3 sets its limits. The default runs both ends of that range.

Returns: A TimeInvarianceResult.

Raises

ExceptionWhen
ValueErrorfor no sweep rate, a rate outside 2 s to 5 s per decade, or a bank with no bands.