# Room to room: partition, receiving room, criterion

A machine runs in one room, a wall separates that room from an occupied one,
and someone wants to know what the occupant hears. It is a short chain, and
every link of it is a piece the library already had: the reverberant level
the machine builds up on the source side, the transmission loss of the wall,
the absorption of the receiving room, and the criterion curve the result is
laid against. What was missing was the joint, and the joint is the one place
where the arithmetic surprises people: **the noise reduction is not the
transmission loss of the wall.**

`noise_control.room_to_room` is that joint, and this page walks Norton &
Karczub's worked problems through it end to end. The reference throughout is
Norton, M. P. & Karczub, D. G., *Fundamentals of Noise and Vibration
Analysis for Engineers* (2nd ed., Cambridge University Press 2003),
Chapter 4: §4.6 for the sound power models, §4.9 for the room-to-room
balance and §4.10 for the enclosure. Its problems 4.16, 4.18 and 4.21 carry
printed octave-band answers, and all three are pinned in the
[conformance report](https://jmrplens.github.io/phonometry/reference/conformance/).

Where the *partition itself* comes from is a different question, answered by
[Panel sound insulation](https://jmrplens.github.io/phonometry/buildings/design/panel-sound-insulation/) (mass law, coincidence,
double leaves, the plateau method) or by measurement. This page takes the
transmission loss as given, exactly as a hand calculation does.

## 1. What the balance says

Norton's §4.9 balances the steady-state power in the receiving room: what
crosses the partition equals what the room absorbs plus what leaks back
through the partition. Replacing intensities with mean-square pressures and
taking logarithms gives Equation (4.101),

$$
\text{NR} = \text{TL}
- 10\log_{10}\!\left[\frac{S_\mathrm{w}}{S_2 \alpha_2 + \tau S_\mathrm{w}}\right],
$$

with $\text{NR} = L_{p1} - L_{p2}$ the noise reduction between the two
reverberant fields, $\text{TL} = 10\log_{10}(1/\tau)$ the transmission loss of the
partition (the quantity UNE calls the sound reduction index $R$), $S_\mathrm{w}$ the
area of the partition and $S_2 \alpha_2$ the equivalent absorption area of
the receiving room.

Read the logarithm and the whole page follows. A **large partition into a
hard room** delivers *less* than its transmission loss: a lot of area
radiating into a room with nothing to soak it up. A **small partition into
a well-absorbing room** delivers *more*. The two rooms and the wall are not
separable, which is why quoting a wall's $R_\mathrm{w}$ and stopping is not an
answer.

The $\tau S_\mathrm{w}$ term is the power the partition itself passes back into the
source room. At any realistic transmission loss it is worth a few
hundredths of a decibel, so it is off by default and
`include_partition_transmission=True` switches it on.

## 2. Three partitions, one receiving room

Norton's problem 4.21 (printed pp. 586-587) is the comparison the equation
was made for: two 13 mm gypsum wallboards with a 64 mm air gap, a 125 mm
plastered brick wall and a double brick wall with a 50 mm cavity, all
speaking into the same 8 m x 9 m x 3 m receiving room through the same
8 m x 3 m opening.

```python
import numpy as np
from phonometry import (
    SourceRoom, equivalent_absorption_area, room_to_room_transmission,
)

bands = [125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0]

# Receiving room 8 x 9 x 3 m: walls 102 m2, floor and ceiling 72 m2 each.
receiving = equivalent_absorption_area([
    (102.0, [0.04, 0.04, 0.09, 0.15, 0.17, 0.23]),   # walls
    (72.0,  [0.02, 0.06, 0.14, 0.37, 0.60, 0.66]),   # floor
    (72.0,  [0.30, 0.20, 0.15, 0.05, 0.05, 0.05]),   # ceiling
])
print(np.round(receiving, 1))
# [27.1 22.8 30.1 45.5 64.1 74.6]   m2, band by band

partitions = {
    "Two 13 mm wallboards, 64 mm gap": [18, 27, 37, 45, 43, 39],
    "125 mm plastered brick":          [36, 36, 40, 46, 54, 57],
    "Double brick, 50 mm cavity":      [37, 41, 48, 60, 61, 61],
}
for name, tl in partitions.items():
    res = room_to_room_transmission(
        bands, tl, 8.0 * 3.0, receiving,
        source=SourceRoom(level=90.0), label=name,
    )
    print(f"{name:32s} {np.round(res.noise_reduction, 1)}")
# Two 13 mm wallboards, 64 mm gap  [18.5 26.8 38.  47.8 47.3 43.9]
# 125 mm plastered brick           [36.5 35.8 41.  48.8 58.3 61.9]
# Double brick, 50 mm cavity       [37.5 40.8 49.  62.8 65.3 65.9]
```

Those are Norton's printed answers to the tenth of a decibel. Look at what
the receiving room did to them. At 125 Hz the room absorbs 27.1 m² against a
24 m² partition, so every wall delivers half a decibel *more* than its
transmission loss. At 250 Hz the ceiling has stopped absorbing and the floor
has not started, the room is down to 22.8 m², and every wall now delivers
0.2 dB *less*. By 4 kHz the carpet and the walls together give 74.6 m² and
the same brick wall is worth 4.9 dB more than its transmission loss. The
same three walls, ranked the same way, but the numbers a specification would
quote move by more than 5 dB depending on a room the wall never touches.

## 3. The chain, end to end

Problem 4.18 (printed pp. 585-586) is the whole calculation, and it starts
one step earlier: the source-room level is not given, only the blower's
free-field sound power level. Two decisions turn that into $L_{p1}$, and both
are Norton's.

**The reverberant field is what drives the partition.** The receiver of
interest is the wall, not a point beside the machine, so the level that
matters is $L_{p1} = L_W + 10\log_{10}(4/R_1)$. That is `steady_state_spl` with
`distance=None`, the $r \to \infty$ limit of the same Bies Equation (6.43)
the library has always used for a receiver at a distance.

**The problem asks for a conservative estimate, and conservative has a
meaning.** The blower sits on the floor along the middle of a wall, in the
intersection of two large flat surfaces, so $Q = 4$. Norton's §4.6
Table 4.5 lists three sound power models: a *constant-power* source radiates
the same $\Pi_0$ wherever it stands, a *constant-volume* source is loaded by
the nearby boundaries and radiates $\Pi_0 Q$, and a *constant-pressure*
source, a theoretical floor, radiates $\Pi_0 / Q$. Real machines sit between
the first two whenever they are closer to the boundary than a wavelength,
and the constant-volume model is the upper bound. Here it is worth
$10\log_{10} 4 = 6.02\ \text{dB}$, and without it the printed answers come out
6 dB low.

```python
from phonometry import (
    DesignCriterion, SourceRoom, equivalent_absorption_area, mean_absorption,
    room_constant, room_to_room_transmission,
)

bands = [125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0]
ceiling = [0.07, 0.20, 0.40, 0.52, 0.60, 0.67]      # absorbent ceiling
walls = [0.03, 0.03, 0.03, 0.04, 0.05, 0.07]        # both rooms

# Plant room 8 x 10 x 3 m: bare floor, absorbent ceiling, 108 m2 of wall.
plant = [(80.0, [0.01, 0.01, 0.015, 0.02, 0.02, 0.02]),
         (80.0, ceiling), (108.0, walls)]

# Operator room 5 x 5 x 3 m: carpet, same ceiling and walls.
operator = [(25.0, [0.08, 0.24, 0.57, 0.69, 0.71, 0.73]),
            (25.0, ceiling), (60.0, walls)]

chain = room_to_room_transmission(
    bands,
    [39.0, 42.0, 50.0, 58.0, 63.0, 67.0],       # TL of the separating wall
    5.0 * 3.0,                                  # the wall is 5 m x 3 m
    equivalent_absorption_area(operator),
    source=SourceRoom(
        power_level=[105.0, 103.0, 98.0, 108.0, 107.0, 109.0],
        room_constant=room_constant(268.0, mean_absorption(plant)),
        directivity=4.0,                        # floor-wall intersection
        model="constant_volume",                # the conservative bound
    ),
    criterion=DesignCriterion(target=45.0),
    label="Plant room to operator room",
)

for row in chain.table():
    print(f"{row['label']:<28} "
          f"{[round(float(v), 1) for v in row['values']]}")
```

```text
Source sound power level     [105.0, 103.0, 98.0, 108.0, 107.0, 109.0]
Source room level            [107.0, 101.7, 93.8, 102.4, 100.6, 101.9]
Partition transmission loss  [39.0, 42.0, 50.0, 58.0, 63.0, 67.0]
Receiving-room absorption    [5.5, 12.8, 26.1, 32.6, 35.8, 39.2]
Noise reduction              [34.7, 41.3, 52.4, 61.4, 66.8, 71.2]
Receiving room level         [72.4, 60.4, 41.4, 41.0, 33.9, 30.7]
NC 45                        [60.0, 54.0, 49.0, 46.0, 44.0, 43.0]
Required transmission loss   [51.4, 48.4, 42.4, 53.0, 52.9, 54.7]
```

Norton's printed answer is 72.3 / 60.4 / 41.4 / 41.0 / 33.8 / 30.7 dB, which
this reproduces to a tenth. Two rows are worth staring at. The **noise
reduction climbs from 34.7 dB to 71.2 dB** while the transmission loss only
climbs from 39 to 67, because the operator room's absorption grows seven
fold across the range while the wall is fixed at 15 m²; the little room does
half the work at high frequency and none at all at 125 Hz. And the
**required transmission loss row is not monotone**: the wall needs 51.4 dB
at 125 Hz where it has 39, and 42.4 dB at 500 Hz where it already has 50. A
low-frequency problem, in a wall that is over-specified in the middle.

<picture><source media="(prefers-color-scheme: dark)" srcset="https://raw.githubusercontent.com/jmrplens/phonometry/main/.github/images/room_to_room_chain_dark.svg"><img src="https://raw.githubusercontent.com/jmrplens/phonometry/main/.github/images/room_to_room_chain.svg" alt="Octave-band chart of Norton's plant-room problem from 125 Hz to 4 kHz: the source-room level runs from 107 dB down to 94 dB at 500 Hz and back to 102 dB, the receiving-room level falls steadily from 72 dB to 31 dB and crosses the NC 45 curve between 250 and 500 Hz, and on the right axis the transmission loss of the wall rises from 39 to 67 dB while the noise reduction it delivers rises from 35 to 71 dB, crossing the transmission loss between 250 and 500 Hz" width="88%"></picture>

*The chain of problem 4.18. The receiving-room spectrum crosses the NC 45
curve between 250 and 500 Hz, so the two low bands are the whole problem.
The right axis is the point of Equation (4.101): the noise reduction the
wall delivers starts 4 dB below its transmission loss and ends 4 dB above
it, and the crossing is where the operator room's absorption grows past the
15 m² of the wall.*

<details>
<summary>Show the code for this figure</summary>

```python
import matplotlib.pyplot as plt

# `chain` is the RoomToRoomResult built above.

# One line: both reverberant spectra, the criterion curve and the noise
# reduction against the transmission loss on the twin axis.
chain.plot()
plt.show()

# By hand, from the per-band fields the result carries:
fig, ax = plt.subplots()
ax.semilogx(chain.frequencies, chain.source_level, "s--", label="Source room")
ax.semilogx(chain.frequencies, chain.received_level, "o-", label="Receiving room")
ax.semilogx(chain.frequencies, chain.criterion_curve, ":", label="NC 45")
twin = ax.twinx()
twin.plot(chain.frequencies, chain.transmission_loss, "--", label="TL")
twin.plot(chain.frequencies, chain.noise_reduction, "-.", label="NR")
plt.show()
```

</details>

## 4. The verdict, and the number to specify

The result rates itself. `.rating` is the ANSI/ASA S12.2-2019 rating of the
received spectrum, `.criterion_curve` is the design curve sampled at the
analysis bands, `.exceedance` is the band-by-band excess and
`.meets_target` is the plain verdict a design sheet writes down.
`.required_transmission_loss` is Equation (4.101) solved for $\text{TL}$,
which is the number that goes into a specification.

```python
print(chain.meets_target)                       # False
print(round(chain.rating.rating, 1))            # 61.7, governed by 125 Hz
print([round(float(v), 1) for v in chain.exceedance])
# [12.4, 6.4, -7.6, -5.0, -10.1, -12.3]

deficit = chain.required_transmission_loss - chain.transmission_loss
print([round(float(v), 1) for v in deficit])
# [12.4, 6.4, -7.6, -5.0, -10.1, -12.3]
```

The deficit and the exceedance are the same six numbers, which is the whole
content of the chain: a decibel too much in the room is a decibel too little
in the wall. Whether that low-frequency deficit is worth chasing with mass,
a cavity or a second leaf is what
[Panel sound insulation](https://jmrplens.github.io/phonometry/buildings/design/panel-sound-insulation/) is for.

The verdict is deliberately the band-by-band test, not the rating. A
spectrum can rate NC-38 and still poke through the NC 45 curve in one band,
because the standard's two-step designation procedure and a design sheet's
"no band above the curve" are different questions.

## 5. An enclosure against a criterion

Problem 4.16 (printed pp. 584-585) asks the same question about an
enclosure instead of a partition: a refrigeration compressor makes a
reverberant level in its room, the technician needs that level down to an
NC-45 curve, and the enclosure walls have to make up the difference. Norton
derives the enclosure equation from the same power balance as §4.9 and gets
Equation (4.115),

$$
\text{IL} = \text{TL} - 10\log_{10}(S_\mathrm{E} / R_\mathrm{i}),
$$

with $S_\mathrm{E}$ the external radiating area and $R_\mathrm{i}$ the room constant of the
enclosure interior, machine surface included. Solved for the panels,
$\text{TL} = \text{IL} + 10\log_{10}(S_\mathrm{E} / R_\mathrm{i})$, which is
`enclosure_required_transmission_loss`.

```python
import numpy as np
from phonometry import enclosure_required_transmission_loss, mean_absorption

bands = [63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0, 8000.0]
wool = [0.10, 0.20, 0.45, 0.65, 0.75, 0.80, 0.80, 0.80]   # 50 mm blanket
concrete = [0.01, 0.01, 0.01, 0.02, 0.02, 0.02, 0.03, 0.03]

lp1 = np.array([72.0, 79.0, 81.0, 84.0, 83.0, 81.0, 80.0, 75.0])   # unenclosed
nc45 = np.array([67.0, 60.0, 54.0, 49.0, 46.0, 44.0, 43.0, 41.0])  # target

# Enclosure 2.5 x 3.5 x 2.5 m on the concrete floor: the walls and roof
# radiate (38.75 m2) and their inner faces carry the lining. The rest of the
# interior is the uncovered floor plus the five exposed faces of the
# 1.5 x 2.5 x 1.5 m machine, both with the absorption of concrete.
radiating = 2 * (2.5 * 2.5) + 2 * (3.5 * 2.5) + 2.5 * 3.5
machine = 2 * (1.5 * 1.5) + 2 * (2.5 * 1.5) + 1.5 * 2.5
bare_floor = 2.5 * 3.5 - 1.5 * 2.5

required = enclosure_required_transmission_loss(
    lp1 - nc45,
    radiating,
    radiating + bare_floor + machine,
    mean_absorption([(radiating, wool), (bare_floor + machine, concrete)]),
    frequencies=bands,
    model="norton",
)
print(np.round(required.panel_transmission_loss, 1))
# [14.5 25.3 28.9 34.4 35.2 34.7 34.6 31.6]
```

Norton's printed answer is 14.4 / 25.2 / 28.9 / 34.4 / 35.2 / 34.7 / 34.7 /
31.6 dB, matched to 0.11 dB, which is the resolution of his own one-decimal
rounding. The shape is the useful part: **the requirement peaks at 1 kHz and
falls away at both ends**, because at 63 Hz the mineral wool absorbs almost
nothing and the level to lose is only 5 dB, while at 8 kHz the compressor
has quietened down. A panel chosen for its 500 Hz to 2 kHz figure is the
right panel here.

Two footnotes on that snippet, both about being faithful to the source.
`model="norton"` matters: the library's default enclosure model is Bies,
Hansen & Howard's Equation (7.111), which carries a $0.3$ inside the
logarithm and so floors the insertion loss of a fully lined enclosure at
$\text{TL} + 5.2\ \text{dB}$. Norton's Equation (4.115) has no such floor.
The two agree
within a few tenths while the interior is hard and diverge once the lining
takes over, and reproducing a published answer means using the model its
author used. `ENCLOSURE_MODELS` lists both.

And the NC-45 column is Norton's own, taken from his problem statement. It
reads 41 dB in the 8 kHz band where ANSI/ASA S12.2-2019 Table 1 (which
`nc_curve` implements) reads 42 dB; they agree in every other band. Using
the printed column keeps the oracle the published one.

## 6. What the prediction does not know

Norton's answer to problem 4.21 ends with the caveat that matters more than
any of the arithmetic above: the measured noise reduction runs below the
prediction because of **flanking transmission through mechanical connections
and air leaks**. A ceiling void carried over the partition, a service
penetration, a door undercut, or the wall simply not reaching the structural
slab, and the equation's answer becomes an upper bound.

The clip below draws what the equation leaves out. The chain of section 3
prices the direct path only, the **Dd** route through the partition; the
other three pulses leave the source room over the flanking walls, floor or
ceiling — **Ff** flank to flank, **Fd** flank to partition, **Df** partition
to flank — and re-radiate on the far side without ever passing through the
transmission loss the calculation used. Each path shrinks at every element
and junction it crosses, which is why no single one has to be large for the
sum of the three to dominate a good partition.

<picture><source media="(prefers-color-scheme: dark)" srcset="https://raw.githubusercontent.com/jmrplens/phonometry/main/.github/images/anim_flanking_paths_dark.gif"><img src="https://raw.githubusercontent.com/jmrplens/phonometry/main/.github/images/anim_flanking_paths.gif" alt="Animation: energy pulses leaving the source room over the direct Dd path and the flanking Ff, Fd and Df paths, shrinking at each element and junction, every path label lighting up as its pulse re-radiates into the receiving room" width="640" height="360" loading="lazy"></picture>

[Watch the high-resolution video (WebM)](https://raw.githubusercontent.com/jmrplens/phonometry/main/.github/images/anim_flanking_paths.webm)

`DesignCriterion.flanking_penalty` is the explicit debit for that, in
decibels off the
predicted noise reduction. It is not a model, it is a place to record the
allowance and have it show up in `.table()` and in the required
transmission loss rather than get lost:

```python
# The chain of section 3 again, with 3 dB allowed for flanking and leaks.
honest = room_to_room_transmission(
    bands, [39.0, 42.0, 50.0, 58.0, 63.0, 67.0], 15.0,
    equivalent_absorption_area(operator),
    source=SourceRoom(level=chain.source_level),
    criterion=DesignCriterion(target=45.0, flanking_penalty=3.0),
)
print(np.round(honest.received_level, 1))
# [75.4 63.4 44.4 44.  36.9 33.7]      every band 3 dB worse
```

Where the flanking paths *are* modelled rather than allowed for, the
prediction models of EN 12354 are the right tool, and those live in
[Building sound insulation prediction](https://jmrplens.github.io/phonometry/buildings/design/insulation-prediction/) and
[Flanking transmission](https://jmrplens.github.io/phonometry/buildings/insulation/flanking-lab/).

The other assumption is diffusivity. Equation (4.101) is a diffuse-field
balance in both rooms, so it has nothing to say below each room's Schroeder
frequency (`schroeder_frequency`), where discrete modes rule. The 5 m x 5 m
x 3 m operator room above, 75 m3, has for a
half-second reverberation time a Schroeder frequency of 163 Hz, which is
exactly why the 125 Hz band of problem 4.18 - the band that governs the
whole answer - should be read as an estimate and not as a number.

## What this guide covers

**Covered.** The Norton & Karczub §4.9 power balance (Eq. 4.101) as
`room_to_room_transmission`, with `SourceRoom`, `equivalent_absorption_area`,
`mean_absorption` and `room_constant`; the source-room level from a sound power
level through the §4.6 Table 4.5 source models — constant power, constant
volume, constant pressure — and the directivity of the machine's position;
`DesignCriterion` with its target, its flanking allowance and its ANSI/ASA
S12.2-2019 rating, NC by default and RC Mark II with
`DesignCriterion(family="RC")`, plus `.required_transmission_loss`,
`.exceedance`, `.meets_target` and `.table()`; and the §4.10 enclosure equation
(Eq. 4.115) through `enclosure_required_transmission_loss` in both interior
models listed by `ENCLOSURE_MODELS`.

**Not covered.** The transmission loss of the partition itself, which is
measured or predicted elsewhere; flanking as a modelled path rather than the
flat allowance used here; and the leaks and openings of an enclosure, which
need the composite of
[Industrial noise control](https://jmrplens.github.io/phonometry/devices/noise-control/noise-control/). The whole chain is a diffuse-field
argument, so it says nothing below either room's Schroeder frequency, or closer
to a surface than roughly half a wavelength.

## See also

- [Panel sound insulation](https://jmrplens.github.io/phonometry/buildings/design/panel-sound-insulation/):
  where the transmission loss this page consumes comes from.
- [Building sound insulation prediction](https://jmrplens.github.io/phonometry/buildings/design/insulation-prediction/)
  and [Flanking transmission](https://jmrplens.github.io/phonometry/buildings/insulation/flanking-lab/):
  the EN 12354 models for the flanking paths this page only debits.
- [Field sound insulation](https://jmrplens.github.io/phonometry/buildings/insulation/insulation-field/):
  how the same room pair is measured, and the $D_\mathrm{nT}$ and $R'$ a test report
  hands back.
- [Room-noise criteria](https://jmrplens.github.io/phonometry/buildings/rooms/room-noise/): the NC and
  RC Mark II families the verdict is written in.
- [Industrial noise control](https://jmrplens.github.io/phonometry/devices/noise-control/noise-control/):
  the enclosure of section 5 as a construction, with its leaks and its
  measurement standards.
- [Sound power](https://jmrplens.github.io/phonometry/devices/emission/sound-power/): the machine $L_W$
  the whole chain starts from.
- API reference:
  [`noise_control.room_to_room`](https://jmrplens.github.io/phonometry/reference/api/noise_control/room-to-room/).

## References

- Norton, M. P., & Karczub, D. G. (2003). *Fundamentals of noise and
  vibration analysis for engineers* (2nd ed.). Cambridge University Press.
  [doi:10.1017/CBO9781139163927](https://doi.org/10.1017/CBO9781139163927).
  The sound power models of §4.6 (Table 4.5, Eqs. 4.53-4.56), the
  room-to-room balance of §4.9 (Eqs. 4.92-4.101), the enclosure design
  equation of §4.10 (Eqs. 4.102-4.115), and the worked problems 4.16, 4.18
  and 4.21 with their printed octave-band answers, which this guide is built
  around.
- Bies, D. A., Hansen, C. H., & Howard, C. Q. (2017). *Engineering noise
  control* (5th ed.). CRC Press.
  [doi:10.1201/9781351228152](https://doi.org/10.1201/9781351228152). The
  steady-state room relations (§6.4, Eqs. 6.43-6.44) behind
  `steady_state_spl` and `room_constant`, and the enclosure insertion loss
  of §7.4.2 (Eqs. 7.103, 7.111) that is the library's default enclosure
  model.
- ANSI/ASA S12.2-2019. *Criteria for evaluating room noise*. The NC curves
  of Table 1 and the RC Mark II family of Annex D that the chain is rated
  against.
- Kuttruff, H. (2016). *Room acoustics* (6th ed.). CRC Press. The Schroeder
  frequency (Eq. 3.44) that bounds the diffuse-field assumption from below.